Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
2.
J Clin Gastroenterol ; 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38277501

RESUMO

BACKGROUND AND AIMS: The application of endoscopic suturing has revolutionized defect closures. Conventional over-the-scope suturing necessitates removal of the scope, placement of the device, and reinsertion. A single channel, single sequence, through-the-scope suturing device has been developed to improve this process. This study aims to describe the efficacy, feasibility, and safety of a through-the-scope suturing device for gastrointestinal defect closure. METHODS: This was a retrospective multicenter study involving 9 centers of consecutive adult patients who underwent suturing using the X-Tack Endoscopic HeliX Tacking System (Apollo Endosurgery). The primary outcomes were technical success and long-term clinical success. Secondary outcomes included adverse events, recurrence, and reintervention rates. RESULTS: In all, 56 patients (mean age 53.8, 33 women) were included. Suturing indications included fistula repair (n=22), leak repair (n=7), polypectomy defect closure (n=12), peroral endoscopic myotomy (POEM) site closure (n=7), perforation repair (n=6), and ulcers (n=2). Patients were followed at a mean duration of 74 days. Overall technical and long-term clinical success rates were 92.9% and 75%, respectively. Both technical and clinical success rates were 100% for polypectomies, POEM-site closures, and ulcers. Success rates were lower for the repair of fistulas (95.5% technical, 54.5% clinical), leaks (57.1%, 28.6%), and perforations (100%, 66.7%). No immediate adverse events were noted. CONCLUSION: This novel, through-the-scope endoscopic suturing system, is a safe and feasible method to repair defects that are ≤3 cm. The efficacy of this device may be better suited for superficial defects as opposed to full-thickness defects. Larger defects will need more sutures and probably a double closure technique to provide a reinforcement layer.

3.
Endosc Int Open ; 11(11): E1035-E1045, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37954107

RESUMO

Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an emerging procedure that lacks technical standardization with limited adoption beyond expert centers. We surveyed high-volume endosonographers about the technical aspects of EUS-GE to describe how the procedure is currently performed at expert centers and identify targets for standardization. Methods Invitations to complete an electronic survey were distributed to 21 expert EUS practitioners at 19 U.S. centers. Respondents were surveyed about technical aspects of EUS-GE, indications, efficacy, safety, and attitudes toward the procedure. Results All 21 (100%) invited expert endoscopists completed the survey. Nine (42.9%) reported performing >10 EUS-GEs in the last 12 months. About half (47.6%, 10/21) puncture the target loop prior to lumen-apposing metal stent (LAMS) introduction, most often to confirm the loop is jejunum. No respondents reported guidewire placement prior to LAMS introduction. Most (71.4%, 15/21) do not use a guidewire at any time, while 28.6% (6/21) reported wire placement after distal flange deployment to secure the tract during apposition. Eight (38.1%, 8/21) reported at least one major adverse event, most commonly intraperitoneal LAMS deployment (87.5%, 7/8). Factors most often reported as advantageous for EUS-GE over enteral stenting included lack of papilla interference (33.3%, 7/21) and decreased occlusion risk (23.8%, 5/21). Conclusions Significant variation in performance technique for EUS-GE exists among expert US endoscopists, which may hinder widespread adoption and contribute to inconsistencies in reported patient outcomes. The granularity provided by these survey results may identify areas to focus standardization efforts and guide future studies on developing an ideal EUS-GE protocol.

4.
VideoGIE ; 8(11): 462-463, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38026715

RESUMO

Video 1Case presentation of EUS-guided Braun-type enteroenterostomy for the management of an afferent limb-type obstruction in a patient with prior surgical gastrojejunostomy.

5.
Curr Treat Options Gastroenterol ; 21(2): 172-184, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37284352

RESUMO

Purpose of review: Bariatric and metabolic endoscopic therapies provide an option for patients seeking clinically significant weight loss with fewer adverse events than conventional bariatric surgery. Our aims are to provide an overview of the current state of primary endoscopic treatment options for weight loss and to emphasize the importance of including these therapies when presenting weight loss options to qualified patients. Recent findings: Bariatric endoscopy procedures are associated with a lower adverse event rate when compared to bariatric surgery and result in more weight loss than most existing pharmacotherapies approved by the Food and Drug Administration. Summary: Sufficient evidence exists to implement bariatric endoscopic therapies-namely, the intragastric balloon and endoscopic sleeve gastroplasty-as safe and effective treatment options for weight loss when used in combination with lifestyle changes. However, bariatric endoscopy remains an underutilized option by weight management providers. Future studies are needed to identify patient and provider-level barriers to adopting endoscopic bariatric therapies as an option for the treatment of obesity.

6.
Gastrointest Endosc ; 98(4): 629-633.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37385547

RESUMO

BACKGROUND AND AIMS: No studies have evaluated trainees' outcomes when learning ERCP with patients in the supine and prone positions simultaneously. We aimed to assess whether patient position impacts procedural outcomes and learning curve. METHODS: We prospectively evaluated patients undergoing ERCP by a supervised advanced endoscopy trainee (AET) at a tertiary care center. Adult patients with native papillae were included. The AET was universally given 5 attempts per cannulation. Outcomes were evaluated quarterly. RESULTS: Successful cannulation was achieved in 44 supine (69%) and 17 prone (68%) patients (P = .95). Although mean time to reach the papilla was shorter in the supine patient position, time to biliary cannulation (7.8 vs 9.4 minutes, P = .53) and number of attempts were similar. A stepwise increase was seen in cannulation rates throughout the academic year (P < .01) and increased more in supine patients (P = .01). Procedure and total room times were shorter in supine patients. CONCLUSIONS: Shorter procedure and room turnover times and a comparable cannulation rate were found for supine versus prone ERCP.


Assuntos
Sistema Biliar , Colangiopancreatografia Retrógrada Endoscópica , Adulto , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Decúbito Ventral , Curva de Aprendizado , Cateterismo/métodos
8.
Am Surg ; 89(4): 707-713, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34384255

RESUMO

BACKGROUND: We conducted this study to compare the weight loss outcome of intragastric balloons (IGBs) in conjunction with pharmacotherapy vs IGB and intensive lifestyle changes alone. METHODS: This was a multicenter, non-randomized, retrospective study involving 4 academic hospitals. Patients underwent IGB placement with or without concomitant anti-obesity pharmacotherapy. The primary outcome was percent total weight loss (TBWL) after IGB placement at 6 and 12 months. RESULTS: This study included 102 patients, with 23 patients (mean age 46.6 years, 82.6% female) treated with IGB/pharmacotherapy and 79 patients (mean age 46.0 years, 88.6% female) treated with IGB/lifestyle modifications. Patients had a 100% follow-up rate at 6 and 12 months. At 6 months following IGB placement, both groups achieved a similar %TBWL. At 12 months, %TBWL was greater in the IGB/pharmacotherapy group (12.6% ± 1.2 vs 9.7% ± 0.7, P = .04). 65.2% of patients achieved ≥10% TBWL at 12 months in the IGB/pharmacotherapy group, compared to 38.0% in the IGB/lifestyle group (P < .05). The proportion of patients that achieved ≥15% weight loss at 12 months was also significantly different between the IGB/pharmacotherapy and IGB/lifestyle groups (30.4% vs 20.3%, P < .05). DISCUSSION: IGB with concomitant use of pharmacotherapy did not improve weight loss while the IGB was in place compared to IGB and lifestyle changes. However, patients receiving IGB with pharmacotherapy did have greater weight loss and diminished weight regain after balloon removal compared to those receiving just IGB and lifestyle changes.


Assuntos
Balão Gástrico , Obesidade Mórbida , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Balão Gástrico/efeitos adversos , Estudos Retrospectivos , Obesidade/complicações , Redução de Peso , Resultado do Tratamento
10.
VideoGIE ; 7(11): 395-397, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36407038

RESUMO

Video 1Endoscopic repair of gatstrojejunocolic fistala using tandem stent placement with a long covered metal stent.

11.
Gastrointest Endosc ; 95(4): 703-710, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34890694

RESUMO

BACKGROUND AND AIMS: The measurement of the portosystemic pressure gradient (PSG) in patients with advanced liver disease is helpful to assess the severity of portal hypertension (PH) and predict adverse clinical outcomes. EUS-guided PSG (EUS-PSG) measurement is a novel tool to assess PSG in all patients with advanced liver disease. We sought to assess the safety, feasibility, and technical success of simultaneous EUS-PSG measurement and EUS-guided liver biopsy sampling using a single-center experience. METHODS: Patients with suspected liver disease or cirrhosis were enrolled prospectively from 2020 to 2021. EUS-PSG was measured by calculating the difference between the mean portal pressure and the mean hepatic vein pressure. PH was defined as PSG >5 mm Hg and clinically significant PH as PSG ≥10 mm Hg. The primary outcomes were procedural technical success rate and correlation of EUS-PSG with fibrosis stage obtained from concurrent EUS-guided liver biopsy sampling and the correlation of EUS-PSG with patients' imaging, clinical, and laboratory findings. The secondary outcome was occurrence of procedural adverse events (AEs). RESULTS: Twenty-four patients were included in the study. PSG measurement and EUS-guided liver biopsy sampling were successful in 23 patients (technical success rate of 96%) and 24 patients (100% success), respectively. Analysis revealed a significant association between both PSG and liver stiffness measured on transient elastography (P = .011) and fibrosis-4 score (P = .026). No significant correlation was found between the fibrosis stage on histology and measured PSG (P = .559). One mild AE of abdominal pain was noted. Additionally, EUS-PSG was predictive of clinically evident PH. CONCLUSIONS: Simultaneous EUS-PSG measurement and EUS-guided liver biopsy sampling were both feasible and safe and correlated with clinically evident PH and noninvasive markers of fibrosis.


Assuntos
Endossonografia , Hipertensão Portal , Biópsia , Humanos , Hipertensão Portal/complicações , Cirrose Hepática/complicações
14.
Hepatol Commun ; 5(7): 1156-1164, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34278166

RESUMO

Abstinence in patients with alcohol-associated liver disease (ALD) reduces mortality. Most predictors of relapse are not quantifiable, preventing objective analysis of relapse risk and targeted intervention to improve clinical outcomes. We prospectively enrolled patients with ALD from November 2016 to December 2019 and administered a survey with two previously published scales to assess insight into alcohol-use disorder (Hanil Alcohol Insight Scale [HAIS]) and social support (Community Assessment Inventory Scale [CAIS]). Relapse was assessed using surveys and metabolite testing. Unadjusted and prespecified adjusted regression analyses identified predictors of relapse. We enrolled 81% of eligible patients (n = 136), of whom 58 had follow-up data available at the time of analysis. Over a median follow-up of 1 year (interquartile range: 0.5-1.4), 10 patients relapsed (17%). Patients who relapsed were more likely to continue drinking despite either a diagnosis of liver disease or a decompensating event, and were less likely to have been transplanted (all P < 0.05). In unadjusted regression, the HAIS and the "support inside the home" subcategory of the CAIS were predictive of relapse, with odds ratio (OR) = 0.84 (95% confidence interval 0.72-0.97) and 0.85 (0.74-0.97). In adjusted regression, the HAIS was no longer significant, with adjusted OR = 0.70 (0.49-1.00, P = 0.05), whereas the "support inside the home' subcategory of CAIS remained significant, with adjusted OR = 0.69 (0.51-0.92, P = 0.01). Conclusions: Risk factors for relapse in patients with ALD were identified and quantified prospectively, suggesting opportunities to objectively identify patients at risk for relapse as well as to intervene to prevent relapse.

15.
Clin Gastroenterol Hepatol ; 19(5): 1051-1057.e2, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33011292

RESUMO

BACKGROUND AND AIMS: The growing burden of obesity as a chronic disease necessitates a multifaceted approach to management. There has been an increase in the number of available endoscopic therapies for weight management with endoscopic sleeve gastroplasty (ESG) proving to be one of the best options. The long-term efficacy of ESG for management of obesity is not known. This study sought to assess the long-term safety and efficacy of ESG for treatment of obesity. METHODS: This was a prospective cohort study. Participants underwent ESG in a single academic center, and were prospectively enrolled. All procedures were performed by the same therapeutic endoscopist. Patients with a body mass index of >30 kg/m2 (or >27 with comorbidities), who underwent ESG from August 2013 to August 2019 for treatment of obesity were enrolled. Patients were followed for up to 5 years after their procedure. The primary outcome was weight loss at 5 years after the procedure (% total body weight loss, TBWL) RESULTS: 216 patients (68% female) with a mean age of 46±13 years, and mean BMI of 39±6 kg/m2 underwent ESG. Out of 216 patients, 203, 96, and 68 patients were eligible for a 1-, 3-, and 5-year follow up, with complete follow-up rates of 70%, 71%, and 82%, respectively. At 5 years, mean TBWL was 15.9% (95% CI, 11.7-20.5, p < .001) and 90 and 61% of patients maintained 5 and 10% TBWL, respectively. There was an overall rate of 1.3% moderate adverse events (AEs), without any severe or fatal AEs. CONCLUSIONS: Our results suggest that ESG is safe and effective for treatment of obesity, with durable long-term results for at least up to 5 years after the procedure. This procedure should be considered as a reliable option for treatment of obesity.


Assuntos
Gastroplastia , Adulto , Feminino , Gastroplastia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Redução de Peso
16.
Gastrointest Endosc ; 93(5): 1110-1118, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32861753

RESUMO

BACKGROUND AND AIMS: Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease in the United States and is closely associated with obesity and insulin resistance (IR). Weight loss is the best treatment for NAFLD. Endoscopic sleeve gastroplasty (ESG) is a promising endoscopic procedure for treatment of obesity. Our aim is to evaluate the change in IR and estimated hepatic steatosis and fibrosis after ESG. METHODS: One hundred eighteen patients with obesity and NAFLD underwent ESG and were followed for 2 years. Weight loss was evaluated as % total body weight loss. IR was evaluated using the homeostasis model assessment of insulin resistance (HOMA-IR). The previously validated hepatic steatosis index and NAFLD fibrosis score were used to estimate hepatic steatosis and risk of fibrosis. RESULTS: Patients' mean body mass index was 40 ± 7 kg/m2 at baseline. Eighty-four percent of patients completed 2 years of follow-up. At 2 years, the mean total body weight loss was 15.5% (95% confidence interval, 13.3%-17.8%). Patients' HOMA-IR improved significantly from 6.7 ± 11 to 3.0 ± 1.6 after only 1 week from ESG (P = .019) with continued improvement up to 2 years (P = .03). Patients' hepatic steatosis index score improved significantly, decreasing by 4 points per year (P for trend, <.001). Patients' NAFLD fibrosis score improved significantly, decreasing by 0.3 point per year (P for trend, .034). Twenty-four patients (20%) improved their risk of hepatic fibrosis from F3-F4 or indeterminate to F0-F2, whereas only 1 patient (1%) experienced an increase in the estimated risk of fibrosis (P = .02). CONCLUSIONS: Our results suggest a significant and sustained improvement in estimated hepatic steatosis and fibrosis after ESG in patients with NAFLD. Importantly, we showed an early and weight-independent improvement in insulin resistance, which lasted for 2 years after the procedure.


Assuntos
Gastroplastia , Resistência à Insulina , Hepatopatia Gordurosa não Alcoólica , Fibrose , Humanos , Cirrose Hepática/cirurgia , Hepatopatia Gordurosa não Alcoólica/cirurgia , Estudos Prospectivos
17.
Clin Geriatr Med ; 37(1): 103-117, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33213765

RESUMO

Diarrhea is a fairly common problem among the elderly that has a higher morbidity and mortality compared with the general population. There are multiple reasons for diarrhea in the elderly that can be stratified by different mechanisms: infectious, osmotic, secretory, inflammatory, and malabsorptive. Oral hydration and dietary management are the basic management principles for all forms of diarrhea but specific treatment should address the root cause of diarrhea in order to improve outcomes.


Assuntos
Diarreia , Disenteria , Síndromes de Malabsorção , Distribuição por Idade , Fatores Etários , Idoso , Diarreia/diagnóstico , Diarreia/etiologia , Diarreia/terapia , Disenteria/diagnóstico , Disenteria/microbiologia , Disenteria/terapia , Humanos , Síndromes de Malabsorção/diagnóstico , Síndromes de Malabsorção/etiologia , Síndromes de Malabsorção/terapia
18.
Endosc Int Open ; 8(7): E938-E943, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32617398

RESUMO

Background and study aims We compared the diagnostic yield and specimen adequacy in EUS-guided parenchymal biopsies between two types of EUS 19 G core needles. Patients and methods This is a retrospective study of 420 patients at two tertiary medical centers in Florida with unexplained abnormal liver associated tests were referred for EUS evaluation of biliary obstruction and pancreatic pathology. EUS-guided liver biopsy (EUS-LB) was performed at the same session after biliary obstruction was excluded. We compared intact specimen length (ISL), total specimen length (TSL), complete portal triads (CPT) and adverse events (AE). Welch's T and Tukey tests were used for ISL, TSL and CPT. Results A total of 210 patients underwent EUS-LB using a Franseen needle, 210 patients using a fork-tip needle. Median patient age was 52 years (15.63) and 238 (56.7 %) were female. The fork-tip needle had a mean ISL of 2.7 (1.1 SD) cm, TSL of 6 cm (2.1 SD), and mean 19.5 CPT (8.5 SD) Abdominal pain occurred in 35 patients (17 %) post-procedure and was managed with supportive care. Two patients required intravenous (IV) narcotic administration. Subcapsular hematomas occurred in 1 (0.5 %) patients. The Franseen needle had a mean ISL of 3.1 cm (1.3 SD), TSL of 6.5 cm (2.6 SD), and mean of 24 CPT (8.8 SD). Abdominal pain occurred in four patients (2 %) post-procedure, which resolved in all patients after IV narcotic administration. Subcapsular hematomas occurred in 1 (0.5 %) and bile leak in 1(0.4 %) patients. Conclusions Use of the Franseen needle resulted in better liver core samples than that obtained with a fork-tip needle.

19.
VideoGIE ; 5(3): 123-124, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32154486
20.
Liver Transpl ; 26(2): 238-246, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31553123

RESUMO

The prevalence of advanced liver disease and listing for liver transplantation is increasing. Prior assessments of quality of care neither incorporate nor emphasize the patient perspective on quality of care, which may impact clinical outcomes. Our aim was to identify patients' perceptions on what constitutes high quality of care, comparing the findings to existing frameworks and assessments to determine if a patient-derived tool assessing quality of care could facilitate efforts to improve health care. We conducted semistructured interviews of patients wait-listed for liver transplantation, asking patients to describe the quality of their health care with a specific focus on how coordination, communication, office visits, hospitalizations, and cost affect their perceptions of the quality of their care. Data collection conducted concurrently with analyses determined emerging themes and saturation. Themes were mapped to an existing quality-of-care conceptual framework. Qualitative analysis revealed thematic saturation after 15 interviews, and an additional 15 interviews were analyzed that confirmed thematic saturation, maximizing the strength of the results. The 30 patients had a median age of 56 years (range, 32-72 years) and included 15 (50%) men. Although patients believed they received a high quality of care, which was substantiated on current existing measures, a qualitative analysis suggested that patient priorities emphasized 5 themes not currently assessed: managing expectations, providing education, responding to patient needs, executing the care plan efficiently, and utilizing interdisciplinary communication and coordination of care. In conclusion, transplant candidates perceived 5 themes that constitute quality of care, and existing quality-of-care measures do not assess these domains, suggesting a role for creating a patient-derived quality-of-care tool to improve health care and clinical outcomes.


Assuntos
Transplante de Fígado , Listas de Espera , Adulto , Idoso , Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Qualidade da Assistência à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...